Trimethylsilyl triflate

  • Trimethylsilyl trifluoromethylsulfonate
  • Trimethylsilyl trifluoromethanesulfonate
  • Trimethylsilanol trifluoromethanesulfonate
  • Methanesulfonic acid, trifluoro-, trimethylsilyl ester
Formula
F3CSO2OSi(CH3)3
Structure
Description
Clear slightly yellow liquid.
Uses
Catalyst and silylating agent for organic syntheses.

Registry Numbers and Inventories.
CAS
27607-77-8
EC (EINECS/ELINCS)
248-565-4
EC Class
flammable
R 10 14 34 37
S 26 36/37 45
UN (DOT)
2924
Merck
12,9849
Beilstein/Gmelin
1868911
Canada DSL/NDSL
NDSL
US TSCA
Listed
Austrailia AICS
Listed
New Zealand
Listed
Japan ENCS (MITI)
Listed

Properties.
Formula
C4H9F3O3SSi
Formula mass
222.26
Boiling point, °C
77
Vapor density (air=1)
7.7
Density
1.225 g/cm3 (20 C)
Solubility in water
Insoluble
Refractive index
1.3630 (20 C)

Hazards and Protection.
Storage
Keep away from heat, sparks, and flame. Keep away from sources of ignition. Keep container closed when not in use. Store in a tightly closed container. Keep under a nitrogen blanket. Store in a cool, dry, well-ventilated area away from incompatible substances. Flammables-area.
Handling
Wash thoroughly after handling. Use only in a well ventilated area. Ground and bond containers when transferring material. Use spark-proof tools and explosion proof equipment. Avoid contact with eyes, skin, and clothing. Empty containers retain product residue, (liquid and/or vapor), and can be dangerous. Keep container tightly closed. Avoid contact with heat, sparks and flame. Avoid ingestion and inhalation. Discard contaminated shoes. Do not pressurize, cut, weld, braze, solder, drill, grind, or expose empty containers to heat, sparks or open flames.
Protection
Eyes: Wear appropriate protective eyeglasses or chemical safety goggles as described by OSHA's eye and face protection regulations in 29 CFR 1910.133 or European Standard EN166. Skin: Wear appropriate protective gloves to prevent skin exposure. Clothing: Wear a chemical apron. Wear appropriate protective clothing to prevent skin exposure.
Respirators
A respiratory protection program that meets OSHA's 29 CFR 1910.134 and ANSI Z88.2 requirements or European Standard EN 149 must be followed whenever workplace conditions warrant a respirator's use. Follow the OSHA respirator regulations found in 29CFR 1910.134 or European Standard EN 149. Always use a NIOSH or European Standard EN 149 approved respirator when necessary.
Small spills/leaks
Absorb spill with inert material, (e.g., dry sand or earth), then place into a chemical waste container. Clean up spills immediately, using the appropriate protective equipment. Remove all sources of ignition. Use a spark-proof tool. Provide ventilation. A vapor suppressing foam may be used to reduce vapors.
Stability
Stable at room temperature in closed containers under normal storage and handling conditions.
Incompatibilities
Strong oxidizing agents.
Decomposition
Carbon monoxide, oxides of sulfur, carbon dioxide, hydrogen fluoride, silicon oxide.

Fire.
Flash Point,°C
38
Fire fighting
Wear a self-contained breathing apparatus in pressure-demand, MSHA/NIOSH (approved or equivalent), and full protective gear. During a fire, irritating and highly toxic gases may be generated by thermal decomposition or combustion. Will burn if involved in a fire. Use water spray to keep fire-exposed containers cool. Containers may explode in the heat of a fire. Reacts violently with water. Extinguishing media: For small fires, use dry chemical, carbon dioxide, water spray or alcohol-resistant foam. For large fires, use water spray, fog, or alcohol-resistant foam. Use water spray to cool fire-exposed containers. Water may be ineffective. Do NOT get water inside containers. Do NOT use straight streams of water.
Fire potential
Flammable/combustible material. May be ignited by heat, sparks or flames.
Hazards
Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapor explosion hazard indoors, outdoors or in sewers.
Combustion products
Fire will produce irritating, corrosive and/or toxic gases.
Health
3
 
Flammability
3
 
 
Reactivity
2
 

Health.
Exposure effects
   Ingestion
May cause severe and permanent damage to the digestive tract. Causes gastrointestinal tract burns.
   Inhalation
May cause irritation of the respiratory tract with burning pain in the nose and throat, coughing, wheezing, shortness of breath and pulmonary edema. Causes chemical burns to the respiratory tract. Inhalation may be fatal as a result of spasm, inflammation, edema of the larynx and bronchi, chemical pneumonitis and pulmonary edema. Vapors may cause dizziness or suffocation.
   Skin
Causes skin burns.
   Eyes
Causes eye burns.

First aid
 
   Ingestion
Do NOT induce vomiting. If victim is conscious and alert, give 2-4 cupfuls of milk or water. Never give anything by mouth to an unconscious person. Get medical aid immediately.
   Inhalation
Get medical aid immediately. Remove from exposure to fresh air immediately. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. DO NOT use mouth-to-mouth respiration.
   Skin
Get medical aid immediately. Flush skin with plenty of soap and water for at least 15 minutes while removing contaminated clothing and shoes. Wash clothing before reuse. Destroy contaminated shoes.
   Eyes
Get medical aid immediately. Do NOT allow victim to rub or keep eyes closed. Extensive irrigation is required (at least 30 minutes).

Transport.
UN number
2924
Response guide
Hazard class
3
Packing Group
I; II; III
 
HS Code
2931 00 95